PCB design guide
Via types, via covering and special holes explained
Vias carry signals and power between copper layers, and other holes hold screws, connectors or let your board sit on another board. This guide explains each type in plain words, which option to choose in our online calculator, and what changes the price.
Get an instant quoteThrough-hole, blind and buried vias
A via is a small plated hole that connects copper on one layer to copper on another. There are three basic kinds, and they differ in which layers they reach.
| Via type | Which layers it connects | Typical use |
|---|---|---|
| Through-hole via | Drilled through the whole board, from the top layer to the bottom layer. | The standard via on almost every 2- to 16-layer board. Cheapest and easiest to make. |
| Blind via | Starts on an outer layer and stops at an inner layer. You can see it from one side only. | Dense designs (fine-pitch BGAs, phones, compact modules) where you need routing space on the other side. |
| Buried via | Connects inner layers only. It is not visible from either outer surface. | Very dense multilayer boards where outer-layer space is fully used. |
Blind and buried vias are reviewed by our team
Via covering options in our calculator
Under High-spec Options → Via covering you choose how the via holes are finished. The choice matters most when you plan to assemble the boards.
| Option | What it means | Good for | Assembly notes |
|---|---|---|---|
| Tented (standard) | The solder mask covers the via pad and the hole opening. | Most boards. Protects vias from shorts and dirt. | Recommended default. Solder will not flow into covered vias. |
| Untented | The via pad and hole are left open (no solder mask). | Test points on vias, or when you want to probe or solder to a via. | Keep untented vias away from SMD pads, or solder paste can flow into them. |
| Plugged | The hole is sealed with solder mask ink or plugging material, but the surface is not made flat and plated over. | Stopping solder and flux passing through, and helping vacuum hold-down during assembly. | Better than tented for nearby fine-pitch parts. Not ideal directly inside an SMD pad. |
| Epoxy filled & capped | The hole is completely filled with epoxy (resin), sanded flat and plated over with copper. | Via-in-pad under BGA and QFN pads. | Gives a flat, solderable pad with no hole. The usual choice for via-in-pad. |
| Copper paste filled & capped | The hole is filled with conductive copper paste, made flat and plated over. | Via-in-pad where you also want better heat or current flow through the via. | Flat pad like epoxy fill, with extra thermal and electrical conduction. |
For rigid boards, all five covering options are offered at every layer count in our calculator (the via covering choice is not shown for flexible PCBs). In the same section you can also set the via plating method. Leave it on “Not specified” unless your design truly needs a particular method — a suitable method is then chosen in production.
Via-in-pad under BGA and QFN parts
Via-in-pad means placing a via inside an SMD pad instead of next to it. It is common under fine-pitch BGAs (no room for dog-bone fan-out) and under the large thermal pad of QFN parts.
Why the via must be filled and capped
What goes wrong with open vias
Thermal vias under QFN pads
BGA, LGA and 0201 parts get an engineering review
Minimum via size, aspect ratio and the 4-wire Kelvin test
Smaller vias save routing space but need a more precise drilling and plating process, so they cost more.
| Setting in our calculator | What it does |
|---|---|
| Standard via (default) | 0.3 mm drill with a 0.4 mm pad on 4-layer boards and 0.45 mm on 6+ layers. No extra charge. Used for all 1- and 2-layer boards. |
| Smaller via classes (4+ layers) | Drill sizes of 0.25, 0.2, 0.15 and 0.1 mm, each with a matching minimum pad. Choose the class that fits the smallest via in your Gerber; we try to read it from your drill file. |
| 0.1 mm vias | Need a board 1.0 mm thick or less and an ENIG or OSP finish (not HASL). |
| 4-wire Kelvin test | Added automatically on 4+ layer boards when your smallest via drill is below 0.3 mm. On 4- and 6-layer boards some small-via classes also need TG155 material; the calculator switches this for you. |
What is aspect ratio?
Why a 4-wire Kelvin test?
Castellated (plated half) holes
Castellated holes are plated holes cut in half along the board edge. They let you solder a small board flat onto a bigger board, the way many Wi-Fi, Bluetooth and power modules are mounted.
| Board type | Castellated holes in our calculator |
|---|---|
| Rigid, 1 layer | Not available |
| Rigid, 2 to 16 layers | Available — choose “Castellated holes: Yes” |
| Flexible PCB | Available |
Design tips (general guidance): draw the full round pad and hole across the board outline so that half stays after routing, keep the pads on both top and bottom layers, and leave a little spacing between neighbouring half holes so they do not bridge when soldered.
Mechanical holes: plated, non-plated, slots, countersinks and press-fit
| Hole type | What it is | When to use it | How to order |
|---|---|---|---|
| Plated hole (PTH) | Hole walls are copper plated and connected to pads. | Through-hole component leads, connectors, grounded mounting holes. | Standard — just draw it in your drill file. |
| Non-plated hole (NPTH) | Bare hole with no copper inside. | Mounting screws that must stay isolated, plastic locating pegs. | Standard — put it in the non-plated drill file or mark it clearly. |
| Slot | An oval or long hole, plated or non-plated. | Connectors and power parts with flat pins, DC jacks, USB shells. | Draw it as a slot in the drill file or on the outline/mechanical layer. |
| Countersink hole | A cone-shaped opening on top of the hole. | Flat-head screws that must sit flush with the board surface. | High-spec Options → Countersink holes, 90° or 135°. Mark the holes in your files. |
| Press-fit hole | A plated hole made to a tight tolerance so a pin is pressed in without solder. | Press-fit connectors, often on backplanes and thick boards. | High-spec Options → Press-fit holes (±0.05 mm tolerance), 4+ layer boards. |
Tell us which holes are special
Edge plating and backdrilling
Edge plating
Backdrilling
How these options affect price and engineering review
Every board is checked by our engineers before production. Here is how the hole and via choices usually fit in.
- 1
Pick the options in the online calculator
Via covering, minimum via, castellated holes, countersink, press-fit, edge plating and backdrilling all live under High-spec Options. The price updates as you choose. Standard tented through vias add nothing.Tip: Choose the via class that fits the smallest via in your design — not a smaller one. Smaller classes usually add cost.
- 2
Order and pay
The online price includes GST and shipping. You pay at order time by online payment or bank transfer. - 3
Engineering check of your files
Our engineers compare your Gerber and drill files with the options you picked. If the files need a different option (for example a smaller via than selected), we tell you the new price. You can accept and pay the difference, or cancel with a refund. - 4
Special structures are quoted by our team
Blind and buried vias and other HDI builds, and boards outside the online range (above 16 layers, or materials other than FR-4 and flex), are priced by our team — use Send for quote. See PCB capabilities for the full online range, and the glossary for any term you are unsure about.
Frequently asked questions
Related guides
Still have a question?
Send us your files or call us — our engineers will help you choose the right options for your boards and assembly.
Streamline your innovation with