+91 8866188126 [email protected]

PCB design guide

Via types, via covering and special holes explained

Vias carry signals and power between copper layers, and other holes hold screws, connectors or let your board sit on another board. This guide explains each type in plain words, which option to choose in our online calculator, and what changes the price.

Get an instant quote

Through-hole, blind and buried vias

A via is a small plated hole that connects copper on one layer to copper on another. There are three basic kinds, and they differ in which layers they reach.

Via typeWhich layers it connectsTypical use
Through-hole viaDrilled through the whole board, from the top layer to the bottom layer.The standard via on almost every 2- to 16-layer board. Cheapest and easiest to make.
Blind viaStarts on an outer layer and stops at an inner layer. You can see it from one side only.Dense designs (fine-pitch BGAs, phones, compact modules) where you need routing space on the other side.
Buried viaConnects inner layers only. It is not visible from either outer surface.Very dense multilayer boards where outer-layer space is fully used.

Blind and buried vias are reviewed by our team

Our online calculator prices standard through-hole vias only. Blind vias, buried vias and other HDI (high-density) structures need extra lamination and drilling steps, so they cannot be priced instantly. Send your files for a quote and our team will review the stack-up and email you a quotation.

Via covering options in our calculator

Under High-spec Options → Via covering you choose how the via holes are finished. The choice matters most when you plan to assemble the boards.

OptionWhat it meansGood forAssembly notes
Tented (standard)The solder mask covers the via pad and the hole opening.Most boards. Protects vias from shorts and dirt.Recommended default. Solder will not flow into covered vias.
UntentedThe via pad and hole are left open (no solder mask).Test points on vias, or when you want to probe or solder to a via.Keep untented vias away from SMD pads, or solder paste can flow into them.
PluggedThe hole is sealed with solder mask ink or plugging material, but the surface is not made flat and plated over.Stopping solder and flux passing through, and helping vacuum hold-down during assembly.Better than tented for nearby fine-pitch parts. Not ideal directly inside an SMD pad.
Epoxy filled & cappedThe hole is completely filled with epoxy (resin), sanded flat and plated over with copper.Via-in-pad under BGA and QFN pads.Gives a flat, solderable pad with no hole. The usual choice for via-in-pad.
Copper paste filled & cappedThe hole is filled with conductive copper paste, made flat and plated over.Via-in-pad where you also want better heat or current flow through the via.Flat pad like epoxy fill, with extra thermal and electrical conduction.

For rigid boards, all five covering options are offered at every layer count in our calculator (the via covering choice is not shown for flexible PCBs). In the same section you can also set the via plating method. Leave it on “Not specified” unless your design truly needs a particular method — a suitable method is then chosen in production.

Via-in-pad under BGA and QFN parts

Via-in-pad means placing a via inside an SMD pad instead of next to it. It is common under fine-pitch BGAs (no room for dog-bone fan-out) and under the large thermal pad of QFN parts.

Why the via must be filled and capped

An open hole in a pad behaves like a straw. During reflow, molten solder is pulled down into the hole (solder wicking), leaving too little solder on the pad. Filling the via and plating it flat (epoxy or copper filled & capped) turns it back into a normal flat pad.

What goes wrong with open vias

Typical results are weak or open BGA joints, voids under a QFN thermal pad, solder balls on the other side of the board, and parts that lift or tilt. These faults are hard to see because the joints are hidden under the package.

Thermal vias under QFN pads

If you only have a few small thermal vias, tented or plugged from the bottom side can work. For many vias or a high-reliability product, a common rule of thumb is to fill and cap them.

BGA, LGA and 0201 parts get an engineering review

When your assembly contains BGA, LGA or 0201 parts, our engineers review the design before pricing. They will check via-in-pad and via covering together with your stencil and pad design. See the assembly quote FAQ.

Minimum via size, aspect ratio and the 4-wire Kelvin test

Smaller vias save routing space but need a more precise drilling and plating process, so they cost more.

Setting in our calculatorWhat it does
Standard via (default)0.3 mm drill with a 0.4 mm pad on 4-layer boards and 0.45 mm on 6+ layers. No extra charge. Used for all 1- and 2-layer boards.
Smaller via classes (4+ layers)Drill sizes of 0.25, 0.2, 0.15 and 0.1 mm, each with a matching minimum pad. Choose the class that fits the smallest via in your Gerber; we try to read it from your drill file.
0.1 mm viasNeed a board 1.0 mm thick or less and an ENIG or OSP finish (not HASL).
4-wire Kelvin testAdded automatically on 4+ layer boards when your smallest via drill is below 0.3 mm. On 4- and 6-layer boards some small-via classes also need TG155 material; the calculator switches this for you.

What is aspect ratio?

Aspect ratio is board thickness divided by the via drill size. A 1.6 mm board with a 0.2 mm via has a ratio of 8:1. The higher the ratio, the harder it is to plate the hole walls evenly. As general guidance, keep through vias at a modest ratio and use a thinner board or a larger drill if you can.

Why a 4-wire Kelvin test?

The standard flying-probe test (100% and free on every board) finds opens and shorts. The 4-wire Kelvin test also measures the tiny resistance of each via, so it can catch thin or cracked plating inside very small vias that would otherwise pass.

Castellated (plated half) holes

Castellated holes are plated holes cut in half along the board edge. They let you solder a small board flat onto a bigger board, the way many Wi-Fi, Bluetooth and power modules are mounted.

Board typeCastellated holes in our calculator
Rigid, 1 layerNot available
Rigid, 2 to 16 layersAvailable — choose “Castellated holes: Yes”
Flexible PCBAvailable

Design tips (general guidance): draw the full round pad and hole across the board outline so that half stays after routing, keep the pads on both top and bottom layers, and leave a little spacing between neighbouring half holes so they do not bridge when soldered.

Mechanical holes: plated, non-plated, slots, countersinks and press-fit

Hole typeWhat it isWhen to use itHow to order
Plated hole (PTH)Hole walls are copper plated and connected to pads.Through-hole component leads, connectors, grounded mounting holes.Standard — just draw it in your drill file.
Non-plated hole (NPTH)Bare hole with no copper inside.Mounting screws that must stay isolated, plastic locating pegs.Standard — put it in the non-plated drill file or mark it clearly.
SlotAn oval or long hole, plated or non-plated.Connectors and power parts with flat pins, DC jacks, USB shells.Draw it as a slot in the drill file or on the outline/mechanical layer.
Countersink holeA cone-shaped opening on top of the hole.Flat-head screws that must sit flush with the board surface.High-spec Options → Countersink holes, 90° or 135°. Mark the holes in your files.
Press-fit holeA plated hole made to a tight tolerance so a pin is pressed in without solder.Press-fit connectors, often on backplanes and thick boards.High-spec Options → Press-fit holes (±0.05 mm tolerance), 4+ layer boards.

Tell us which holes are special

If you select countersink or press-fit holes, list the hole positions and sizes in a drawing or in the PCB remark, so our engineers can check them against your files. If they cannot tell which holes are meant, they will need to contact you before production.

Edge plating and backdrilling

Edge plating

Copper is plated along the side walls of the board edge and joined to your ground plane. It is used for EMI shielding, for grounding the board to a metal enclosure and in RF designs. Show the plated edges on a mechanical layer and select “Edge plating: Yes”.

Backdrilling

In a thick multilayer board, a via that only needs to reach an inner layer leaves an unused “stub” below it. At high data rates this stub reflects the signal. Backdrilling drills out the stub from the other side. Available for 4+ layer boards; send a drill file that marks the backdrilled vias and their depth.

How these options affect price and engineering review

Every board is checked by our engineers before production. Here is how the hole and via choices usually fit in.

  1. 1

    Pick the options in the online calculator

    Via covering, minimum via, castellated holes, countersink, press-fit, edge plating and backdrilling all live under High-spec Options. The price updates as you choose. Standard tented through vias add nothing.

    Tip: Choose the via class that fits the smallest via in your design — not a smaller one. Smaller classes usually add cost.

  2. 2

    Order and pay

    The online price includes GST and shipping. You pay at order time by online payment or bank transfer.
  3. 3

    Engineering check of your files

    Our engineers compare your Gerber and drill files with the options you picked. If the files need a different option (for example a smaller via than selected), we tell you the new price. You can accept and pay the difference, or cancel with a refund.
  4. 4

    Special structures are quoted by our team

    Blind and buried vias and other HDI builds, and boards outside the online range (above 16 layers, or materials other than FR-4 and flex), are priced by our team — use Send for quote. See PCB capabilities for the full online range, and the glossary for any term you are unsure about.

Frequently asked questions

Choose Tented. It is the standard option, costs nothing extra and suits most boards. Change it only if you need open vias for probing or via-in-pad under fine-pitch parts.

No. Plugged vias are sealed so solder and flux cannot pass through, but the surface is not made flat and plated. Epoxy or copper filled & capped vias are completely filled and plated over, so you can place a pad directly on top of them.

Not always. Coarser-pitch BGAs can often be routed with a via next to each pad (dog-bone). Fine-pitch BGAs usually need via-in-pad, and then the vias should be filled and capped. Boards with BGA parts are reviewed by our engineers before assembly pricing.

On 4+ layer boards we add it automatically when your smallest via drill is below 0.3 mm. It measures the resistance of each small via to catch weak plating that a normal open/short test can miss.

Not through the online calculator. Castellated holes are available on rigid boards with 2 to 16 layers and on flexible boards. A 2-layer board is usually the simplest choice for a module.

They are not priced instantly. Send your files with Send for quote and our team will review the stack-up and email you a quotation.

Related guides

Still have a question?

Send us your files or call us — our engineers will help you choose the right options for your boards and assembly.

Streamline your innovation with seamless PCB ordering.

For More Details Contact Us